DENIOS AG
Dehmer Strasse 58-66
32549 Bad Oeynhausen
br>Tel.: +49 5731753-0
Email: info@denios.ie
Internet: www.denios.ie

Fire-rated storage container RFP 615.30

Item number: 274735W

  • Best option when larger quantities of hazardous materials need to be stored in a separate fire compartment and no safety clearances to avoid exposure to fire on both sides can be maintained.
  • For the storage, dispensing or removal of flammable and water-polluting substances.
  • Install directly next to the external wall of neighbouring buildings or as a fire-rated separate area (REI 90), e.g. in a production hall. Exception: peroxide stores.
  • On request available with variable shelf heights.
  • Water law tested, one-piece, hot-dip galvanised 5 mm spill pallet in the lower storage level.
  • Storage levels fitted with removable, hot-dip galvanised grids (max. load capacity 1,250 kg/m²).
  • Long-lasting corrosion protection with fully-galvanised base material and high-quality 2K paint (RAL 9002, grey-white).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Lockable, self-closing EI₂ 90-C wing doors on the long side meeting EN 13501-2, tested to EN 1634-1 or country-specific design with a door opening angle of 90 ° / 102 °/ 115 °/ 128 °.
  • Accessible-underneath versions are installed on a separately-supplied concrete pad. This means they can easily be loaded with a high-lift truck, for example. For the wide version (RFP 615.20 and .30), the store has two concrete pads of the same size.
  • Door variants: long side with EI₂ 90-C door to EN 13501-2, tested to EN 1634-1 or country-specific version. A door sequence controller ensures the doors close reliably. Door opening angle: 90 °, 102 °, 115 °, 128 °. Security lock for protection against unauthorised access.
  • Points to consider when storing flammable materials: structural equipotential bonding by earthing the steel frame construction and technical ventilation.
  • Accessible-underneath versions are installed on a separately-supplied concrete pad. This ensures easy access and loading using a high lift truck for example. For the wide version, the store is fitted with two concrete pads of the same size.

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

The roof drainage counteracts loads from standing water on the roof. The rainwater is directed via the roof profile to the two short sides of the room and is channeled to an outlet either through the right or left corner profile or through both. From there, it can be directed to a drainage system on site, e.g. via a drainage pipe.

Prerequisites for storing flammable liquids

(Flashpoint ≤ 60 °C, classified as H226, H225 or H224)

  • Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
  • Country-specific requirements for air exchange rate
  • Specifications in accordance with HSG71
  • Specifications in accordance with ATEX Directive 2014/34/EU
Full description

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • Best option when larger quantities of hazardous materials need to be stored in a separate fire compartment and no safety clearances to avoid exposure to fire on both sides can be maintained.
  • For the storage, dispensing or removal of flammable and water-polluting substances.
  • Install directly next to the external wall of neighbouring buildings or as a fire-rated separate area (REI 90), e.g. in a production hall. Exception: peroxide stores.
  • On request available with variable shelf heights.
  • Water law tested, one-piece, hot-dip galvanised 5 mm spill pallet in the lower storage level.
  • Storage levels fitted with removable, hot-dip galvanised grids (max. load capacity 1,250 kg/m²).
  • Long-lasting corrosion protection with fully-galvanised base material and high-quality 2K paint (RAL 9002, grey-white).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Lockable, self-closing EI₂ 90-C wing doors on the long side meeting EN 13501-2, tested to EN 1634-1 or country-specific design with a door opening angle of 90 ° / 102 °/ 115 °/ 128 °.
  • Accessible-underneath versions are installed on a separately-supplied concrete pad. This means they can easily be loaded with a high-lift truck, for example. For the wide version (RFP 615.20 and .30), the store has two concrete pads of the same size.
  • Door variants: long side with EI₂ 90-C door to EN 13501-2, tested to EN 1634-1 or country-specific version. A door sequence controller ensures the doors close reliably. Door opening angle: 90 °, 102 °, 115 °, 128 °. Security lock for protection against unauthorised access.
  • Points to consider when storing flammable materials: structural equipotential bonding by earthing the steel frame construction and technical ventilation.
  • Accessible-underneath versions are installed on a separately-supplied concrete pad. This ensures easy access and loading using a high lift truck for example. For the wide version, the store is fitted with two concrete pads of the same size.

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

The roof drainage counteracts loads from standing water on the roof. The rainwater is directed via the roof profile to the two short sides of the room and is channeled to an outlet either through the right or left corner profile or through both. From there, it can be directed to a drainage system on site, e.g. via a drainage pipe.

Prerequisites for storing flammable liquids

(Flashpoint ≤ 60 °C, classified as H226, H225 or H224)

  • Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
  • Country-specific requirements for air exchange rate
  • Specifications in accordance with HSG71
  • Specifications in accordance with ATEX Directive 2014/34/EU

Technical data

Model RFP 615.30
Clear bay depth [mm] 1.440
Dimensions (without equipment) W x D x H [mm] 6882 x 1784 x 3594
Bay dimensions W x D x H [mm] 2700 x 1.440 x 1331
Door version hinged door
Door design 2 x 2-wing
Load capacity [kg/m²] 1250
Sump capacity [l] 2800
Colour Grey white
RAL Code 9002
Capacity IBC / CP / EP / drum 8 / 8 / 12 / 32
Number of storage levels 2
Weight [kg] 5370

Documents

Do you need help?
We work hard to give you good advice.
Free Expert Advice +44 1952 811 991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

Menu
Log in
Your basketAdded to basket
Go to basket
We would be pleased to provide you with advice!

Give us a call or fill out the form and we will get back to you as soon as possible.

Mon - Thu: 08:30 - 17:00 | Fri: 08:30 - 16:00
i

Calls are handled by our UK team. All sales are processed via our German parent company so are VAT* / tariff free where applicable. *Must be fully IE VAT registered

Use code DEN10 at checkout for 10% off ALL of our catalogue products. Cannot be combined with other promotions, discounts or other special prices. Does not apply to open quotations.