DENIOS AG
Dehmer Strasse 58-66
32549 Bad Oeynhausen
br>Tel.: +49 5731753-0
Email: info@denios.ie
Internet: www.denios.ie

Fire-rated storage container WFP-X 22 Li-Ion

Item number: 274139W

  • Areas of application: Manual storage for smaller module sizes / Intermediate storage for shipping or for faulty lithium batteries / Storage room for electrical appliances or for an electric vehicle (prototype) / Test room with various facilities (personnel air lock, hazardous materials workstation, system monitoring, etc.).
  • Fire-rated stores: Tested and approved as a complete system with 90 minutes fire protection (F 90) from inside and outside. Internationally, versions to meet country-specific legislation (e.g. REI 120). Install directly next to the external wall of neighbouring buildings or as a fire-rated separate area, e.g. in a production hall.
  • Tested, single-piece spill pallet with easily removable hot-dip galvanised grids (load capacity: 1000 kg / m²).
  • External cladding uses galvanised components with 2 layers of paint give long lasting protection. Fire protection panels (A class material, non-combustible) with high insulation properties.
  • Door variants: 1 or 2-wing EI₂ 90-C doors, various door positions. For 2-wing doors, the door sequence controller ensures reliable closure of the doors.
  • Additional advantages: low entry height of 147 mm and precise roof drainage.
  • Structural analysis: to Eurocode 3 (EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m²

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Full description

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • Areas of application: Manual storage for smaller module sizes / Intermediate storage for shipping or for faulty lithium batteries / Storage room for electrical appliances or for an electric vehicle (prototype) / Test room with various facilities (personnel air lock, hazardous materials workstation, system monitoring, etc.).
  • Fire-rated stores: Tested and approved as a complete system with 90 minutes fire protection (F 90) from inside and outside. Internationally, versions to meet country-specific legislation (e.g. REI 120). Install directly next to the external wall of neighbouring buildings or as a fire-rated separate area, e.g. in a production hall.
  • Tested, single-piece spill pallet with easily removable hot-dip galvanised grids (load capacity: 1000 kg / m²).
  • External cladding uses galvanised components with 2 layers of paint give long lasting protection. Fire protection panels (A class material, non-combustible) with high insulation properties.
  • Door variants: 1 or 2-wing EI₂ 90-C doors, various door positions. For 2-wing doors, the door sequence controller ensures reliable closure of the doors.
  • Additional advantages: low entry height of 147 mm and precise roof drainage.
  • Structural analysis: to Eurocode 3 (EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m²

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Technical data

Model WFP-X 22 Li-Ion
Dimensions (without equipment) W x D x H [mm] 8858 x 2878 x 3009
Internal dimensions W x D x H [mm] 8420 x 2560 x 2500
Storage area [m²] 22
Door position Short side
Door version hinged door
Door design 1-wing
Door hinge right
Insulation Heat insulation
Fire resistance 90 minutes
120 minutes
Load capacity [kg/m²] 1000
Sump capacity [l] 3000
Interior height [mm] 2500 mm
Weight [kg] 4869

Documents

Do you need help?
We work hard to give you good advice.
Free Expert Advice +44 1952 811 991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

Menu
Log in
Added to basket
Go to basket
We would be pleased to provide you with advice!

Give us a call or fill out the form and we will get back to you as soon as possible.

Mon - Thu: 08:30 - 17:00 | Fri: 08:30 - 16:00
i

Calls are handled by our UK team. All sales are processed via our German parent company so are VAT* / tariff free where applicable. *Must be fully IE VAT registered

Use code DEN10 at checkout for 10% off ALL of our catalogue products. Cannot be combined with other promotions, discounts or other special prices. Does not apply to open quotations. IMPORTANT: our warehouse will close on the 17th of December, with the last date for dispatch being the 16th. It will reopen on the 2nd of January 2025.